Huawei Technologies Co. Ltd PRU11WIFI 用户手册

下载
页码 303
DBS3900 LampSite 
Installation Guide 
11 (Optional) Installing the EXD3902 and Cables 
 
Issue 08 (2016-05-30) 
Huawei Proprietary and Confidential         
Copyright © Huawei Technologies Co., Ltd. 
230 
 
 
Remove only the waterproof blocks for cables to be installed. 
----End 
11.5.5 Installing an Ethernet Cable 
This section describes how to install an Ethernet cable. 
Context 
 
The Ethernet cable must be of Category 5e (enhanced) or higher. 
 
Ethernet cables are not delivered, and they must be prepared onsite. You need to use a 
network cable tester to test the Ethernet cable connection. 
 
The INPUT port is for connecting to the RHUB, and the OUTPUT port is for connecting to the pRRU. 
Procedure 
Step 1  Make the Ethernet cables. 
1. 
Assemble an RJ45 connector and an Ethernet cable by following instructions in 
Assembling the Unshielded RJ45 Connector and the Ethernet Cable, Assembling the 
Shielded RJ45 Connector and the Ethernet Cable. 
 
Follow pin assignment instructions described in section Ethernet Cable in DBS3900 LampSite Hardware 
Description
 to assemble the RJ45 connector and the Ethernet cable. Otherwise, the transmission signal 
quality deteriorates and CPRI links may be disconnected. 
2. 
Check whether the made RJ45 connector is qualified by following instructions in 
Checking the Appearance of Metal Contact Strips. 
3. 
To complete the assembly of the other end, repeat 
. 
4. 
Check whether the touch points on the connectors at both ends are normally conducted 
and well contacted and whether the connections are correct by following instructions in 
Testing the Connection of Assembled Cables of Installation Reference
Step 2  Connect the RJ45 connector of the cable connecting the RHUB to the INPUT port on the 
EXD3902 and the RJ45 connector of the cable connecting the pRRU to the OUTPUT port on 
the EXD3902. Press the cables into the clips, as shown in Figure 11-23.