DBS3900 LampSite 
Installation Guide 
6 Installing an RHUB 
 
Issue 08 (2016-05-30) 
Huawei Proprietary and Confidential         
Copyright © Huawei Technologies Co., Ltd. 
48 
 
For details about the cable connections in the different scenarios, see 6.4.3 Cable Connections. 
The Ethernet cable connections between RHUB and pRRUs are the same. The following 
section describes the connections between RHUB-Extender-pRRU3901 as an example. 
In the outdoor scenario, PoE surge protector is needed to provide surge protection for the 
Ethernet ports. For details about the installation of PoE surge protector, see 12 (Optional) 
Installing the PoE Surge Protector and Cables. 
Procedure 
Step 1  Make the Ethernet cables. 
1. 
Assemble an RJ45 connector and an Ethernet cable by following instructions in 
Assembling the Unshielded RJ45 Connector and the Ethernet Cable of Installation 
Reference
 
Follow pin assignment instructions described in section Ethernet Cable in DBS3900 LampSite Hardware 
Description
 to assemble the unshielded RJ45 connector and the Ethernet cable. Otherwise, the 
transmission signal quality deteriorates and CPRI links may be disconnected. 
2. 
Check whether the made RJ45 connector is qualified by following instructions in 
Checking the Appearance of Metal Contact Strips. 
3. 
To complete the assembly of the other end, repeat 
. 
4. 
Check whether the touch points on the connectors at both ends are normally conducted 
and well contacted and whether the connections are correct by following instructions in 
Testing the Connection of Assembled Cables of Installation Reference
Step 2  Connect the RJ45 connector at the other end of the Ethernet cable to any port ranging from 
CPRI_E0 to CPRI_E7 on the RHUB panel based on the engineering design. 
Step 3  Optional: Connect the RJ45 connector at the other end of the Ethernet cable to the output 
port of the Extender. Then, connect the RJ45 connector at one end of another Ethernet cable 
to the input port of the Extender. 
If the Extender is used, the Ethernet cable is divided into two parts, one between the RHUB 
and the Extender and the other between the Extender and the pRRU. 
Step 4  Remove the dustproof cap of the CPRI_E0 port on the pRRU. 
Step 5  Connect the RJ45 connector at one end of the Ethernet cable to the CPRI_E0 port on the 
pRRU panel, as shown in Figure 6-34, Figure 6-35.