Renishaw plc RMI 用户手册
15
Core end flush
with ferrule
Core
Ferrule
Crimp
Cable termination
A ferrule should be crimped onto each cable
core for more positive connection at the terminal
box. To fit a ferrule, insert the prepared core into
ferrule, until the end is flush with the end of the
ferrule as shown below. Then crimp with pliers.
core for more positive connection at the terminal
box. To fit a ferrule, insert the prepared core into
ferrule, until the end is flush with the end of the
ferrule as shown below. Then crimp with pliers.
NOTE:
Maximum total cable length is 50 m (164 ft) at 24V
Standard cable
The RMI standard cable is 15 m (49.2 ft) long,
longer cables are avaible (see page 25).
Cable specification:
Ø7.5 mm (0.29 in), 13 core screened cable,
each core 18 x 0.1 mm.
RMI cable
RMI cable