Set up is done by using the RMP trigger logic
and powering on the RMI at a particular time
during the process.
1.
Use trigger logic to set RMP turn on/ off
modes as desired.
2.
Use trigger logic to access RMP acquisition
mode (turquoise/light blue flashes 2 short
and 1 long).
System setup/establishing RMP-RMI partnership.
RMP-RMI partnership
3.
Power on the RMI.
4.
Wait until RMI signal led flashes green.
WARNING:
When holding the RMP do NOT wrap a
hand, or anything else, around the glass
window.
!
5.
Trigger the probe (min 0.1 sec, max 2 sec).
6.
When the partnership is established the
RMI signal LED will flash red and yellow.
7.
Allow ~10 seconds for both RMP and RMI
to timeout, all RMP LEDs off, RMI signal
LED off. The system is then ready for use.
8.
Note: If the RMP flashes 2 turquoise short
followed by 1 red long it is still trying to
partner an RMI.
Note:
When the RMP and RMI become partners the
RMI records the RMP serial number. It is not
possible for an RMI to be partners with more than
one RMP.
It is possible for an RMP to be partners with more
than one RMI, but the system will not
work correctly if more than one partner RMI is
powered on at any one time.