Renishaw plc RMP60V2 用户手册

下载
页码 47
12
Probe settings
The RMP60 probe can be in one of three modes:
Stand-by mode - The RMP60 is waiting for a
switch on signal.
Operating mode - Activated by one of the
switch on methods described on this page.
In this mode the RMP60 is now ready for use.
Configuration mode - The trigger logic
configuration method allows the following
settings to be configured.
Switch-on / switch-off methods
The following switch on / switch off options
can be configured:
1. Radio on / Radio off
2.
Radio on / Timer off
3. Spin on / Spin off
4. Spin on / Timer off
5. Shank switch on / Shank switch off
Probe settings
Note:
The RMP60 will be switched on after 1 second
in all modes.
After being switched on, the RMP60 must be
on for 1 second minimum (7 seconds for spin
start) before being switched off.