Renishaw plc RMP60V2 用户手册

下载
页码 47
31
Diaphragm replacement
Diaphragm replacement
RMP60 DIAPHRAGMS
The probe mechanism is protected from coolant
and debris by two diaphragms. These provide
adequate protection under normal working
conditions.
The user should periodically check the outer
diaphragm for signs of damage. If this is evident,
replace the outer diaphragm.
The user must not remove the inner diaphragm.
If damaged, return the probe to your supplier.
OUTER DIAPHRAGM INSPECTION
1.
Remove the stylus.
2.
Undo the three M3 front cover screws and
remove the front cover.
3.
Inspect the outer diaphragm for damage.
4.
To remove the outer diaphragm, grip by the
outer edge and pull off.
INNER DIAPHRAGM INSPECTION
5.
Inspect the inner diaphragm for damage.
If damaged return the probe to your supplier.
DO NOT REMOVE THE INNER DIAPHRAGM