Honeywell International Inc. MX2702 用户手册

下载
页码 170
3 - 4
Scanner Trigger Modes
Manual/Serial Trigger, Low Power
You can activate the scanner either by pressing the trigger, or using a serial 
trigger command (see 
Trigger Commands
on page 11-4).  When in manual 
trigger mode, the scanner scans until a bar code is read, or until the trigger is 
released. 
When in serial mode, the scanner scans until a bar code has been read or until 
the deactivate command is sent.  In serial mode, the scanner can also be set to 
turn itself off after a specified time has elapsed (see 
Read Time-Out (Serial Trigger Mode)
Use this selection to set a time-out (in milliseconds) of the scanner’s trigger when 
using serial commands to trigger the scanner.  Once the scanner has timed out, 
you can activate the scanner either by pressing the trigger or using a serial 
trigger command.  After scanning the Read Time-Out bar code, set the time-out 
duration (from 0-300,000 milliseconds) by scanning digits on the 
 inside the back cover, then scanning Save.  
Default = 0 ms (no time-out).
Scanner Power Time-Out Timer
Note: The Scanner Power Time-out Timer option only applies to Manual/Serial 
Trigger.
When there is no activity within a specified time period, the scanner enters low 
power mode.  Scan the Scanner Power Time-Out bar code to change the time-
out duration (in seconds).  Then scan the digit value of the duration (from 1-
10,800 seconds) and the Save bar codes on the 
back cover of this manual.   
Default = 3600 seconds (1 hour).
* Manual/Serial Trigger
Read Time-Out