TRACER 2210/3202 System Manual
Section 4, Network Turnup Procedure
61280012L1-1A
© 2002 ADTRAN, Inc.
33
Customer Provides
The following items are necessary for the installation of the TRACER 2210/3202 system and are not 
provided by ADTRAN:
4 Conductor, 22 or 24 AWG, UV-resistant cable (maximum length 700 ft or 600 ft, respectively)
4.
CABLE ASSEMBLY
The following provides pictorial instructions for assembling the cable between the TRACER 2210 and 
3202 units. The cable length and material should be customized to suit the needs of the application. All of 
the necessary connector pieces are supplied by ADTRAN in your TRACER 2210/3202 shipment.
Figure 1.  Cable Assembly Instructions
1
2
3
4
1
2
3
4
P1
P2
Schematic
1
2
3
4
P1
P2
1 & 2
3 & 
4
1 & 2
3 &
 4
1 & 2
3 & 4
Tracer 3202 base (Version 1)
Tracer 3202 base (Version 2)
1.  Crimp each crimp tube and  wrap 
individually with electrical tape to 
prevent shorting
2.  Wrap the complete bundle with 
electrical tape to protect from  
outside elementsmosture.
Warning: When connecting the 
supplied cable to your in house 
wiring, do not attach the block 
assembly to the TRACER 2210 
base unit until cable assembly is 
complete.