Adtran TRC4108 用户手册
TRACER 4108/4208 System Manual
Section 5 User Interface Guide
612804208L1-1B
© 2003 ADTRAN, Inc.
53
>T1
X
S
TATUS
/C
ONFIGURATION
/L
OOPBACK
> L
OOP
/N
ORMAL
S
TATE
> L
INE
Activates a loopback at the TRACER 4108/4208 T1 framer towards the locally connected T1 equipment
(see Figure 11). Use the
(see Figure 11). Use the
L
INE
loopback to test data path integrity from the TRACER 4108/4208 unit to the
T1 equipment.
Figure 11. T1 Line Loopback
>T1
X
S
TATUS
/C
ONFIGURATION
/L
OOPBACK
> L
OOP
/N
ORMAL
S
TATE
> L
INE
(
REMOTE
)
Activates a loopback at the remote TRACER 4108/4208 T1 framer towards the locally connected T1
equipment (see Figure 11). Use the
equipment (see Figure 11). Use the
L
INE
loopback to test data path integrity from the TRACER 4108/4208
unit to the T1 equipment.
Figure 12. T1 Remote Line Loopback
>T1
X
P
ERFORMANCE
H
ISTORY
Figure 13 shows the T1x Performance History menu page, which displays detailed error statistics for the
T1 link (from both the local and remote TRACER 4108/4208 units) in 15-minute increments.
T1 link (from both the local and remote TRACER 4108/4208 units) in 15-minute increments.
Figure 13. T1x Link Performance History
The following menus for the T1x Performance History apply to all eight available T1
interfaces (A through H).
interfaces (A through H).
24
Hours
7