Installing the LM100 gateway
Page 32
Senstar LM100 Product Guide
Grounding
The gateway requires a single ground reference. Connect the ground lug on the bottom of the 
enclosure to an approved earth ground at the gateway’s location. The earth ground connection 
must be stable and noise free. An improper or unstable earth ground can induce noise in the 
gateway. Do not use the fence structure as an earth ground. Avoid sharp bends in the ground wire. 
I/O ports
The LM100 gateway includes ten I/O ports that can be configured as either inputs or outputs in any 
combination. The I/O ports are accessed through removable screw terminal blocks. Each port has 
an associated LED, which indicates when the port is active (LED ON = port active). The optional 
dry contact input card includes four additional inputs and the optional relay output card includes 
four additional relays to supplement the I/O on the gateway.
I/O port jumpers
Each I/O port includes a pair of configuration jumpers which are set according to the intended use 
of the port. For ports that will be configured as outputs and will source power to an external device, 
and for all inputs, install the shunts on the headers. For ports that will be configured as outputs but 
will not source power (dry contact outputs) park the shunts on a single pin, as indicated in 
Outputs
The gateway’s relay outputs can source up to 100 mA at the same voltage as the gateway’s input 
power in the high side drive configuration. The relays can also be configured to sink up to 100 mA 
as Form A (normally open) or Form B (normally closed) contacts. The capability to source power 
depends on the capacity of the connected power supply. The gateway’s relays can also be 
configured as Form A or Form B dry contact outputs (no power). 
 
illustrates the 
gateway’s five selectable output schematics. 
Note
Consult the local electrical code for grounding information.
Note
The gateway can use either an input card or an output card, not both.
Figure 33: Gateway I/O port jumper settings
 
voltage sourcing outputs and dry contact inputs
dry contact outputs