Deister Electronic GmbH APRBHI 用户手册

下载
页码 19
 
 
 
APR300/400 
 
07.06.05 
Vertraulich / Confidential 
Page 6 of 19 
 
2. 
BASIC operation of APR readers  
2.1  The 8 keys for the operation{ XE "Keyboard" } 
 
•  ON/OFF - Switch power on/off 
•  HOTKEY A Starts a READ and or additional functions 
•  HOTKEY B Starts a READ and or additional functions 
•  F – Switch into MENU Modus  
•  – In MENU Modus one level up 
•  RETURN Conformation of changes in the MENU Modus and one level down 
•  Å - SCROLL up Move or Value higher 
•  Æ - SCROLL down Move or Value lower 
 
2.2  The status messages in the second line of the DISPLAY{ XE 
"Status messages" } 
 
•  Battery empty, if capacity is as low as 5 to 10% 
•  Memory full! , appears if memory is full 
•  Online modus, if the reader is connected with a PC via cable  
•  Cradle, if the reader is connected with a PC via docking station 
•  RAM ERROR, at failures in memory 
 
2.3  The acoustic signals{ XE "Acoustic signals" } 
•  One BEEP = keyboard BEEP 
•  4 times BEEP = OK (ID read) 
•  Long BEEP = NOK (no ID read) 
•  High/low BEEP = double read (into one minute) 
•  Keyboard BEEP but longer = ACTION BEEP