Deister Electronic GmbH MODEL260 用户手册

下载
页码 36
GE Contactless Medium Read-Range Reader Model 260
13
Micro Selection
Micro/5 for 2RP and 8RP installation instructions: refer to the Micro/5 
Installation Guide
IMPORTANT: DO NOT use the Model 260 Reader with a Micro/5 2SRP reader 
processor.
Micro/PX-2000 and Micro/PXN-2000 controllers: refer to the Micro/
PX-2000 
and Micro/PXN-2000 Installation Guide.
Micro/Reader-Junction Box: refer to the point-to-point wiring 
diagrams in this manual.
Reader-to-Micro Wiring Distance
Table  1: Model 260 Current and Cable Distance
Cable Distance
Supply 
Voltage
12 VDC
13.6 VDC
24 VDC
Current
18 AWG
22 AWG
18 AWG
22 AWG
18 AWG
22 AWG
Distance
230 mA 
@12 VDC
928 ft. 
(283 m)
390 ft. 
(119 m)
1,423 ft. 
(434 m)
597 ft. 
(182 m)
4,649 ft.
(1,417 m)
1,949 ft.
(594 m)