6.7 
Tag Related Error Conditions 
 
 
Message  
Description 
No response from tag.  
 
Read attenuation decreased to 0 dB and there 
was no response from the tag (i.e. number of  
read timeouts = read sample size). 
Bad CRC transponder 
 
If number of  good reads = 0, and 50% or more 
of samples are bad CRC
 
Good CRC but Group ID not 65 
Invalid data contents 
Bar code mismatch with tag 
contents 
 
 
 
Serial number or agency ID mismatch with bar 
code information (scanned). 
 
Read margin exceeds limits 
Read Margin is outside allowed range.  
Write margin exceeds limits  
Write margin is outside allowed range.  
Read performance below limit 
Problems reading data from transponder.  
Write performance below limit  
Problems writing data to transponder.  
 
6.8 
Sending Log Files to Mark IV 
The log file generated by the T600 Tag Tester contains important information 
about the tags tested.   
The following minimum procedure is required in terms of the T600 Tag Tester log 
file:  
-  Obtain a RMA number from Mark IV. 
-  Rename the log file to include the RMA number.  
-  Transmit the log file (in its original format) electronically to Mark IV (e-mail, 
floppy, or CD).