Wi Lan Inc EB02 用户手册
Configuration
58
AWE 120-58 Installation & Configuration Guide
Link Statistics Example
6.
Check for BER = 0.0E+00 and CorrP between 15 – 50 dB
.
If the CorrP is <15 dB the receive signal is
probably too weak. If the power is >55 dB the receiving unit is probably saturated.
If you have problems ensure that the unit is configured to its basic default settings (see
, page 99) and reconfigure the unit, or contact Wi-LAN customer support.
7.
To end the test, briefly disconnect power from the unit or press and hold the Mode button to return to
Normal mode.
Normal mode.
BER
Bit Error Rate
MPC
Missed Packet Count
EnvP
Envelope Power—the power of the received signal inlcuding noise,
measured in dB (0–63)
measured in dB (0–63)
CorrP
Correlation Power—the power of the received signal, excluding noise,
measured in dB (0–63)
measured in dB (0–63)
- BER = 0.0E+00, MPC = 0, EnvP = 63, CorrP = 63
| BER = 0.0E+00, MPC = 0, EnvP = 63, CorrP = 63
Bit Error Rate
Missed
Packet
Count
Packet
Count
Envelope Power
Correlation Power
Previous
Sample
Sample
Current
Sample
Sample