3G4000 Wiring Diagrams
12
Figure 2 - Wiring Diagram
1K5
Battery not required
if JP3 is ON
9-14V
DC
/ *700mA
 (max)
Supervision
Relay
Optional
use of PGM
output (See
Programming)
WARNING: 
Incorrect connections may result in PTC failure or improper operation. Inspect wiring and ensure connections are correct before
 turning on.
All circuits are classified for UL
 installations as Power Limited/Class II Power Limited. Do not route any wiring over circuit 
boards. Maintain at least 1” 
(25.4mm) separation. 
A
 minimum 1/4” (6.4mm) separation must be maintained at all points between Power Limited wiring and all ot
her Non-Power Limited 
wiring.  Route wires as indicated in the diagram.
NOTE: For ULC Commercial Burglary Installation requirements please refer to Figures 5, 6, 7 and to the ULC Installation Guide P
/N 29002157.
Telephone Line
Connection
RJ-45
Examples of Control Units/Subscribers Units or Power Supplies compatible 
models:  DSC PC1864, PC1832, PC1616, PC5204, etc.
Electrical Ratings: 13.7 VDC / 700 mA
Power Supply: COM BURG, use listed control panel; RES FIRE/BURG,
use 
ADP1320-NAU/NA
 (US/CDN) and Battery: 7.2V/2.2Ah
For use in dry indoor ordinary locations only
. For installation refer to NFP
A70, 72.
Alarm Control Panel with
Dialler Interface
(Supports Contact ID and 
SIA
 formats)
BA
TTER
Y
Sealed 
Rechargeable
7.2V / 2.2Ah
RM1-UL
 Installations
RM1C-ULC Installations
Connect relay contacts to a zone input on the alarm control 
panel for 3G4000 troubles supervision (24hr-type zone)
T I P
R I N G
Panel Aux 
Power 
or 
External Power Supply 
(13.8V
DC
 required for 
normal, long-term operation)
Typical battery charge: 30-50 mA
Recommended Model: 12V/1.2Ah 
3G4000
TIP
RING
T1
R1
Z1
PGM1
Z2
PGM2
DC IN
+
-
1
2
3
4
5
6
7
9
8
10
WARNING!
HIGH VOL
TAGE. 
DISCONNECT DC 
POWER AND 
TELEPHONE LINES 
PRIOR T
O SER
VICING.
Incorrect connections 
may result in failure
or improper operation.
}
Inputs to be connected
to dry contact outputs
from alarm control panel
(Use No. 26 
A
WG 
wires for the  
connection to PSTN)