ADCP-75-114 • Issue C • June 2001 
Page 9 
©
 2001, ADC Telecommunications, Inc. 
  4.  Position the RIU in the designated mounting space in the rack (per system design) and 
then
  secure  the  mounting  brackets  to the rack using the four machine screws provided 
(use
 #12-24 screws or M6 x 10 screws, whichever is appropriate) as shown in Figure 5.  
    Note: Provide a minimum of 3 inches (76 mm) of clearance space on both the left and right 
sides
 of the RIU for air intake and exhaust.  
16483-B
 
Figure 5. RIU Rack Mount Installation 
2.3.2 Wall-Mount 
Installation 
The
 RIU may be mounted from any flat vertical surface. It is recommended that a backer board 
such
 as 3/4-inch plywood be applied over the mounting surface to provide a secure base for 
attaching
 the RIU. Two mounting holes are provided in the cable management tray for securing 
the
 RIU to the mounting surface. In addition, the mounting brackets may be removed and then 
reinstalled
 in such a way that they can be used for securing the RIU to the mounting surface. 
Either
 method for mounting may be used at the discretion of the installer. The fasteners must be 
provided
 by the installer. Use the following procedure to wall-mount the RIU: 
 
  Warning:  Wet  conditions  increase  the  potential  for  receiving  an  electrical  shock  when 
installing
 or using electrically-powered equipment. To prevent electrical shock, never install 
or
 use electrical equipment in a wet location or during a lightning storm.  
  1.  Obtain the appropriate fasteners (lag bolts, screw anchors, etc.) for securing the RIU to 
the
 mounting surface.  
  2.  If the mounting brackets will be used to secure the RIU to the mounting surface, proceed 
to
 step 3. If the mounting brackets will not be used to secure the RIU to the mounting 
surface,
 skip steps 3 and 4 and proceed to step 5.