ADCP-75-114 • Issue C • June 2001 
Page 15 
©
 2001, ADC Telecommunications, Inc. 
16482-B
ALARM
CONNECTOR
MAJOR
ALARM
WIRES
MINOR
ALARM
WIRES
ALARM CONNECTOR
DETAIL
 
Figure 11. External Alarm System Connections 
  5.  Connect  the  Minor  alarm  wire  pair  to  the  MINOR  COM/NC  or  MINOR  COM/NO 
terminals
 (whichever is required by the external alarm system) on the RIU alarm terminal 
connector
 as shown in Figure 11.  
  6.  Connect  the  Major  and  Minor  alarm  wire  pairs  to  the  appropriate  terminals  on  the 
external
 alarm system.  
  7.  Dress and secure cable. 
2.7  AC Power Connection 
The
 AC power interface between the RIU and the AC power source is supported by a 3-wire 
AC
  power  cord  connector  located  on  the  RIU  front  panel.  The  AC  connector  provides  a 
connection
  point  for  the  power  cord  which  is  provided  separately  with  the  RIU.  Use  the 
following
 procedure to install the AC power cord: 
  1.  Place  the  RIU  AC  power  ON/OFF  switch,  shown  in  Figure  12,  in  the  OFF  position 
(press
 O).