ADC Telecommunications Inc. DVICSRIU800 用户手册
ADCP-75-114 • Issue C • June 2001
Page 16
©
©
2001, ADC Telecommunications, Inc.
16654-A
AC POWER CORD
Figure 12. AC Power Connection
2. Locate the AC power cord which is provided separately with the RIU. Use only the AC
power
cord provided with the RIU or an equivalent UL listed and CSA certified 3-
conductor,
18 AWG cord terminated in a molded-on plug cap rated 125 V, 15 A with a
minimum
length of 6 feet (1.8 m).
Note: The RIU is intended to be used with a 3-wire grounding type plug which has a
grounding
pin. Equipment grounding is to ensure safe operation. Do not defeat the
grounding
means. Verify RIU is reliably grounded when installed.
3. Connect the receptacle end of the power cord to the AC connector on the RIU.
4. Route the plug end of the power cord to the specified AC outlet (per the system design)
4. Route the plug end of the power cord to the specified AC outlet (per the system design)
and
connect plug to outlet.
Warning: The current rating of the RIU is 2 Amps at 120 VAC. Avoid overloading circuits
which
may cause damage to over-current protection devices and supply wiring.
5. Dress and secure cable.
6. When the RIU installation is complete, refer to Section 3 of this manual for the unit turn-
6. When the RIU installation is complete, refer to Section 3 of this manual for the unit turn-
up
and test procedures.