ADC Telecommunications Inc. DVICSRIU800 用户手册

下载
页码 31
ADCP-75-114 • Issue C • June 2001 
Page 16 
©
 2001, ADC Telecommunications, Inc. 
16654-A
AC POWER CORD
 
Figure 12. AC Power Connection 
  2.  Locate the AC power cord which is provided separately with the RIU. Use only the AC 
power
  cord  provided  with  the  RIU  or  an  equivalent  UL  listed  and  CSA  certified  3-
conductor,
 18 AWG cord terminated in a molded-on plug cap rated 125 V, 15 A with a 
minimum
 length of 6 feet (1.8 m).  
    Note:  The  RIU  is  intended  to  be  used  with a 3-wire grounding type plug which has a 
grounding
  pin.  Equipment  grounding  is  to  ensure  safe  operation.  Do  not  defeat  the 
grounding
 means. Verify RIU is reliably grounded when installed.  
  3.  Connect the receptacle end of the power cord to the AC connector on the RIU.  
  4.  Route the plug end of the power cord to the specified AC outlet (per the system design) 
and
 connect plug to outlet.  
 
  WarningThe current rating of the RIU is 2 Amps at 120 VAC. Avoid overloading circuits 
which
 may cause damage to over-current protection devices and supply wiring.  
  5.  Dress and secure cable.  
  6.  When the RIU installation is complete, refer to Section 3 of this manual for the unit turn-
up
 and test procedures.