Wulfsberg Electronics Division 2000-800 用户手册

下载
页码 39
 
P-2000/C-2000/RT-2000 
Operator’s Manual 
 
Page 13 of 39 
Publication No. 150-049105 
P-2000 Operators Manual 
Rev. A 
Oct 2003 
 
Selecting a Standby Channel Using the Cursor/Value Knob 
When the P-2000 first powers on, the selected channels will be set to those that were active when the unit was 
powered down.  To select a different preset channel, do the following: 
Using the cursor knob, put the square cursor around the channel number.  Turn the value knob until the channel is 
your desired channel.  If you wish to make this your active channel, push the transfer button. 
 
 
 
Selecting a Channel Using the Keypad 
Occasionally, it is desirable to select a preset channel by entering its number via the keypad, rather than dialing it in 
with the cursor/value knobs.  This can be performed as follows. 
 
When the user presses the CHAN key, the keypad channel entry mode will begin.  This mode allows the user to tune 
a channel by inputting the desired channel’s number into a field via the keypad.  The figure below depicts this mode 
of channel tuning.  If no keypad input is received for more than 4 seconds, the operation will automatically cancel.  
If the user presses the HOME key, the operation will also cancel.  When the user presses the ENTER key, the 
channel with the number input into the field will be loaded.  If the input channel number is invalid, an error tone will 
sound, and the previous “good” channel will be reinstated.