QMEM Operations
When the user presses the QMEM key, the system will enter the QMEM mode.  This mode allows the user to either
select or program a QMEM location.  When the user presses the QMEM key, then presses a keypad key (0-9), the
channel programmed into the corresponding (0-9) QMEM location shall be loaded into the active channel, and the
previously active channel shall be loaded into the standby channel.  If the user presses the QMEM key, then presses
and holds down a keypad key (0-9) for 3 or more seconds, the current active channel shall be programmed into the
corresponding QMEM location.  If the user does not press any key for more than 4 seconds after pressing the
QMEM key, the QMEM operation shall automatically be cancelled.  The user can also cancel the QMEM operation
by pressing the HOME key.  The figure below shows the QMEM operation in mid stream.
To store a channel into a QMEM position first put the desired channel in the active channel and press the QMEM
button.  The figure below shows what the display will look like.
At this point press and hold button 0-9 until the status line indicates the storage operation is completed, as shown in
the picture below:
To load the active channel using QMEM, simply push the QMEM button followed by a 0-9 button and the
programmed channel will be automatically loaded into the active channel.  If that QMEM position has not been
programmed with a channel, the status line will indicate to the user no channel is programmed.