Controller Operation 
36 
AYC-F/G/M60 Series Installation and Programming Manual 
5.3
 
Auxiliary Input and Output 
For optimum usability in different applications, the controller’s 
auxiliary input and output can be configured in 10 different modes of 
operation (see Sectio
5.4
 
Door Alarms 
Door alarms can be generated by connecting the Auxiliary Input to a 
Door Position Switch. Either Door-Forced or Door-Ajar conditions are 
supported, as well as a configurable delay timer for each alarm type. 
Only one door-alarm is enabled at any one time. Door alarms may 
activate auxiliary output and siren depending on the auxiliary settings. 
5.5
 
Internal Case and Back Tamper 
If the unit is forcibly opened or it is removed from the wall, a tamper 
event is triggered. A tamper output opens sending a signal to the 
connected alarm system (purple wire); the event closes when the 
tamper is closed (case is re-closed or re-attached to the wall). 
The tamper event can also activate the auxiliary output if the 
controller is in Auxiliary Mode 3 (refer to Table 5). 
5.6
 
Lockout Feature (Keypad/Card Tamper) 
If the controller is presented with wrong codes (PIN or card) 
consecutively several times, the unit goes into Lockout mode. 
When a lockout
 
occurs, the controller’s reader and keypad are de-
activated so no codes can be entered until the set lockout period 
expires. 
During Lockout mode, the left LED is Off, the right LED flashes red, 
and the controller beeps every two seconds.