Controller Operation 
AYC-F/G/M60 Series Installation and Programming Manual 
37 
5.7
 
REX Function 
The REX button is connected to Rosslare’s secured intelligent power 
supply. The REX button must be located inside the premises to be 
secured and is used to open the door without the use of a PIN code. It 
is usually located in a convenient location, such as inside the door or 
at a receptionist's desk. The function of the REX button depends on 
whether the Lock Strike Relay is programmed for Fail Safe Operation 
or Fail Secure Operation. 
 
Fail Secure Operation: From the moment the REX button is 
pressed, the door is unlocked until the Lock Strike Release Time 
passes. After this time, the door is locked even if the REX button 
is not released. 
 
Fail Safe Operation: From the moment the REX button is pressed, 
the door is unlocked until the REX button is released, plus the 
Lock Strike Release Time. In this case, the Lock Strike Relay only 
begins its count down once the REX button is released. 
5.8
 
Secured Intelligent Power Supply 
Rosslare’s secured intelligent power supplies are designed for use with 
Rosslare's secured standalone access control units, including the AYC-
F/G/M60 series. The AYC-F/G/M60 units are designed to operate 
indoors and are installed within the secured premises. The units must 
be used with one of Rosslare’s secured intelligent power supplies, 
which provides Lock Strike output and REX input. The AYC-F/G/M60 
and the power supply communicate through a proprietary Rosslare 
protocol, which provides a secure link between them. This in turn 
activates the door lock. 
Each power supply unit contains a speaker connection for all sounder 
abilities. 
For more information, see the 
PS-x25T Installation Manual