Rosslare Enterprises Ltd AYCF6X 用户手册

下载
页码 66
Controller Operation 
AYC-F/G/M60 Series Installation and Programming Manual 
47 
The following subsections describe each Auxiliary mode. 
5.9.9.1
  Auxiliary Mode 0 
Auxiliary input function: Activates the auxiliary output 
Auxiliary output activated by: Valid user code, Auxiliary code, 
Auxiliary input 
For example, in Auxiliary Mode 0, the controller can function as a 
two-door controller. The auxiliary relay is to be attached to the lock 
on the second door. The auxiliary setting defines the door open time 
for the second door. The auxiliary input is to be attached to the REX 
pushbutton for the second door. The Door Monitor input feature for 
the second door is not enabled when using this mode. 
5.9.9.2
  Auxiliary Mode 1 
Auxiliary input function: Toggles Normal/Secure modes 
Auxiliary output activated by: Valid user code, Auxiliary code 
For example, in Auxiliary Mode 1, the controller can function as a 
two-door controller. The auxiliary relay is to be attached to the lock 
on the second door. REX feature for the second door is not enabled 
when using this mode. 
The auxiliary setting defines the door open time for the second door. 
The auxiliary input can switch the mode of operation of the controller 
between Normal and Secure mode. By connecting a switch timer or 
alarm system output to the auxiliary input, the controller can be 
automatically switched from Normal mode (during office hours) to 
Secure mode (after office hours). 
5.9.9.3
  Auxiliary Mode 2 
Auxiliary input function: Toggles normal/secure modes 
Auxiliary output activated by: Asterisk Button (*) 
For example, in Auxiliary Mode 2, the auxiliary relay can function as a 
general purpose time switch that can be activated when the asterisk 
button (*) is depressed. The auxiliary setting establishes for how long 
the auxiliary relay is to be activated. The auxiliary input can switch the 
mode of operation of the controller between Normal and Secure