Controller Operation 
48 
AYC-F/G/M60 Series Installation and Programming Manual 
modes. By connecting a switch timer or alarm system output to the 
auxiliary input, the controller can be automatically switched from 
Normal mode (during office hours) to Secure mode (after office 
hours). 
5.9.9.4
  Auxiliary Mode 3 
Auxiliary input function: Toggles Normal/Secure modes 
Auxiliary output activated by: Alarms 
For example, in Auxiliary Mode 3, the auxiliary output is activated if 
the controller is tampered; that is, if the case is forcibly opened or 
removed from the wall. The auxiliary input can switch the mode of 
operation of the controller between Normal and Secure modes. By 
connecting a switch timer or alarm system output to the auxiliary 
input, the controller can be automatically switched from Normal 
mode (during office hours) to Secure mode (after office hours). 
5.9.9.5
  Auxiliary Mode 4 
Auxiliary input function: Toggles Normal/Secure modes 
Auxiliary output activated by: Direct shunt (explanation below) 
For example, in Auxiliary Mode 4, the controller is capable of 
bypassing an alarm zone by shunting an alarm system’s door sensor. 
The auxiliary output is to be wired in parallel to the door sensor 
output. When in use, the auxiliary output is normally open and the 
door sensor functions normally. When a valid code is entered, the 
auxiliary relay shunts the door sensor for the duration of the shunt 
time, as defined by the auxiliary setting. If the door is left open longer 
than the shunt time, an alarm is triggered.