User Menu Structure 
22 
HLX-24 User Manual 
Select  
To 
Zone Bypass 
Enables you to arm the system by bypassing/un-bypassing 
selected zones (see Sectio
This option is enabled if manual bypass has been enabled by the 
installer. 
Note:  Zone bypass can be triggered only if the zone was 
enrolled. 
Remote Controls 
Enroll remote controls for quick activation of the system (see 
Section 
(M) Private 
Numbers 
Specify up to three private telephone numbers (see Section 
Walk Test 
When entering the detector’s Test mode, the red and green 
LEDs on the panel flash every second simultaneously, and the 
display shows “receiving…”. 
If the alert monitoring station reporting options is enabled, an 
E607 event is transmitted. 
The Walk Test sequence timeout is for 15 minutes. In the last 5 
minutes, a squawk is heard every two seconds in addition the 
green and red LEDs flash simultaneously to indicate that the 
testing period will be terminated in another five minutes. 
If the system walk detector test is terminated, an R607 restore 
event is transmitted (if enabled). 
During the Walk Test, each successful detector violation causes 
a squawk and the signal strength is displayed. 
In the conclusion of the Walk Test, the installer may browse 
through the recorded results by using the Menu button. Each 
browsing of a record is followed by the E613 event transmission 
with the relevant zone indication. 
For 24-H and fire zones, reporting trouble event E380 is sent to 
the monitoring station.