HARRIS CORPORATION MBS800B075 用户手册

下载
页码 100
MM102225V1, Rev. B 
52 
6.5 
BASE STATION TRANSMIT (BSX) FREQUENCY 
ACCURACY TEST (MANDATORY) 
Objective:  The purpose of the Base Station Frequency Test is to verify that the DCX is 
operating on the allocated frequency and compliant with the FCC specifications. 
STEPS 
ACTION 
MISCELLANEOUS 
1. 
Connect the PC to the DCX TERMINAL port. 
 
2. 
Using a suitable console application, enter the 
sequence of commands indicated by the bold 
script in the example on the right to return the 
base station to digital mode. 
offline 
; <Various Shutdown Text is Displayed> 
at@outmode1 
OK 
save_config 
OK 
reboot 
; < The Base Station Reboots > 
3. 
Repeat Steps 1 and 2 for all other DCX units. 
 
4. 
Select the RF GEN screen of the HP 8920 and 
turn off the generator function by selecting the 
Amplitude and pressing the ON/OFF /(YES) 
key. 
 
5. 
Select the RF ANALYZER function of the HP 
8920 and set the following parameters: 
•  Tune Mode: 
Auto 
•  Input Port: 
RF In 
•  Disconnect the I/Q cables to remove 
modulation. 
•  Connect the HP 8920 RF/IN Port to 
Bird Power Monitor TX Output Port. 
 
6. 
Enable an HPA. 
 
7. 
Record TX Frequency shown on Analyzer
11
TOL: Must be + 86Hz. CAUTION:  Lock the 
frequency counter/service monitor to a GPS 
standard and then set the station frequency + 
86Hz.
12
  
8. Disable 
the 
HPA. 
 
9. 
Repeat on all other DCX units. 
 
10. 
Replace I/Q Cables. 
 
                                                           
11
 Refer to APPENDIX L - RECORDED DATA SHEET. 
12
 Ensure the GPS standard is better than 0.01ppm (about 1E-8 or better).