53 
6.6 
TRANSMIT DEVIATION (MANDATORY) 
Objective:  The objective of this test is to ensure that the transmit deviation is correctly 
adjusted. 
STEPS 
ACTION 
MISCELLANEOUS 
1. 
Verify that the HPA transmit Enable/ 
Disable switch is set to the Disable 
position for all HPA’s. 
 
2. 
Select the RF GEN screen and set the 
Amplitude field to Off by pressing the 
ON/OFF / (YES) key. 
 
3. 
Select the AF Analyzer Screen on the 
HP 8920 and configure the following 
parameters: 
•  Set AF Analyzer to “FM Demod” 
•  Set the Detector to “Pk+ - /2” 
•  Set FM Deviation to Ave 10 
Samples. 
 
4. 
Set the following configuration 
parameters on the RF Analyzer screen: 
Tune Mode: 
Auto 
Tune Frequency:  Set for the RF path 
under test. 
Input Port: 
RF In 
Sensitivity: Normal 
IF Filter: 
230KHz 
 
5. 
Set the HPA Enable/Disable switch to 
the Enable position. 
 
6. 
The measured value of FM Deviation 
should be 3.0 kHz ±150 Hz for the 
channel under test. Measure and record 
the indicated FM Deviation on the 
recorded data sheet
13
 
7. 
Disable the HPA. 
 
8. 
Repeat for each RF path. 
 
                                                           
13
 Refer to APPENDIX L - RECORDED DATA SHEET.