TRANSMIT DEVIATION (MANDATORY)
Objective: The objective of this test is to ensure that the transmit deviation is correctly
adjusted.
adjusted.
STEPS
ACTION
MISCELLANEOUS
1.
Verify that the HPA transmit Enable/
Disable switch is set to the Disable
position for all HPA’s.
Disable switch is set to the Disable
position for all HPA’s.
2.
Select the RF GEN screen and set the
Amplitude field to Off by pressing the
ON/OFF / (YES) key.
Amplitude field to Off by pressing the
ON/OFF / (YES) key.
3.
Select the AF Analyzer Screen on the
HP 8920 and configure the following
parameters:
HP 8920 and configure the following
parameters:
• Set AF Analyzer to “FM Demod”
• Set the Detector to “Pk+ - /2”
• Set FM Deviation to Ave 10
• Set the Detector to “Pk+ - /2”
• Set FM Deviation to Ave 10
Samples.
4.
Set the following configuration
parameters on the RF Analyzer screen:
parameters on the RF Analyzer screen:
Tune Mode:
Auto
Tune Frequency: Set for the RF path
under test.
Input Port:
RF In
Sensitivity: Normal
IF Filter:
230KHz
5.
Set the HPA Enable/Disable switch to
the Enable position.
the Enable position.
6.
The measured value of FM Deviation
should be 3.0 kHz ±150 Hz for the
channel under test. Measure and record
the indicated FM Deviation on the
recorded data sheet
should be 3.0 kHz ±150 Hz for the
channel under test. Measure and record
the indicated FM Deviation on the
recorded data sheet
13
.
7.
Disable the HPA.
8.
Repeat for each RF path.
13
Refer to APPENDIX L - RECORDED DATA SHEET.