HARRIS CORPORATION MBS800B075 用户手册

下载
页码 100
MM102225V1, Rev. B 
 
55 
STEPS 
ACTION 
MISCELLANEOUS 
9. 
Press the Enter key on the laptop 
keyboard. 
The status information on the right will 
be displayed on the PC console 
application. Similar to the text found on 
the right. 
Example: buck40:
14
 
buck40-bs1> 
Setting the 
HPA TX 
Power 
 
 
10. 
Enter the command: 
 
at@hpapower[CR] 
Example: Where N is the desired HPA 
power setting to overcome rack losses. 
11. 
Set the HPA Disable/Enable switch to 
Enable
 
12. 
The HPA will send the message shown 
on the right via the DCX to the console 
display and start transmitting. 
HPA> RF enabled by front panel switch. 
 
13. 
Compare the measured value TX Power 
on the HP 8920 to the desired level, 
repeating steps 10-12 as necessary to 
fine-tune the measured level to set the 
prescribed Site ERP. 
Note:  There may be a slight variation 
between the commanded and measured 
power levels.  This may be due to test cable 
losses. Be sure to factor these into the 
measurement process. 
Example: 
Output Power 
43dBm 
Test Cable Loss 
-.8dB 
HP 8920 Reading 
42.2dBm 
14. 
When the final value for TX Power is 
achieved, enter the commands on the 
right. 
save_config [CR] 
reboot [CR] 
15. 
After the DCX has completed its boot 
cycle record the final measured HPA TX 
Power 
level on the collection sheet and 
data sheet
15
 
16. 
Set the tested HPA Enable/Disable 
switch to the Disable position. 
 
17. 
Repeat for each RF channel, leaving 
tested HPA’s in the DISABLED mode. 
 
                                                           
14
 "Buck40", where used in this manual, is only an example of the applicable code. 
15
 Refer to APPENDIX L - RECORDED DATA SHEET.