Installation
TB9300 Installation and Operation Manual
© Tait Limited July 2012
5.1.3
Equipment Ventilation
Always ensure there is adequate ventilation around the base station. 
Notice
Do not operate it in a sealed cabinet. You must keep the 
ambient temperature within the specified range, and we strongly rec-
ommended that you ensure that the cooling airflow is not restricted.
Notice
The cooling fans are mounted on the front panel and will only 
operate when the panel is fitted correctly to the front of the subrack. To 
ensure adequate airflow through the base station, do not operate it for 
more than a few minutes with the front panel removed (e.g. for servicing 
purposes).
5.1.4
Ambient Temperature Sensor
The ambient temperature reading for the base station is provided by the 
temperature sensor located on the front panel circuit board.