Raytheon Anschuetz GmbH High Seas Products NSX-30U 用户手册

下载
页码 296
Synapsis Radar  
with Nautoscan NX Pedestal 
Operator Manual 
 
 
 
 
4265.DOC020102 
2-50 
Edition Sep 2015 
 
2.3.1.9 
Pulse Width Selection (only available in Master mode)
 
The pulse width toggle field allows selection of the desired transmitter pulse 
width for the current range scale selected. If there is no pulse width toggle field, 
this indicates that it is not available for the range currently being used. 
Operator controls 
Task 
 
 
Selecting this toggle field allows the pulse length to 
be switched e.g. from short pulse to medium pulse 
and vice versa to optimize target discrimination with 
respect to the selected range. 
 
 
 
 
Use of a longer pulse improves target reception but, at the 
same time, increases clutter returns. 
When using longer pulses it may be difficult to differentiate 
very close targets. 
When a shorter pulse is used, reception of some weaker 
targets will decrease, but clutter will also decrease, 
resulting in better target detection. 
 
The available pulse width selections for the Radar displays and the Radar 
MTRs are illustrated in Table 2-7. 
Table 2-7 
Pulse width selection on dependency the current range scale 
Selected Range 
Scale in NM 
Default Pulse width  
Manual Set Pulse width 
0.125 
 
 
0.25 
 
 
0.5 
 
 
0.75 
 
 
1.5 
 
 
SP 
SP 
SP 
SP 
M1 
M1 
M1 
M1 
M1 
M2 
SP