VS300 Operations and Maintenance Manual
Operating the transmitter
Issue 0.1  2011-03-11
Page 2-83
Configuring RF drive source
From the front panel UI, you can configure the source of the transmitter’s RF drive (internal or 
external). To view the 
RF Drive Source 
screen, select 
System Settings -> RF Drive Source
 from the 
Main Menu
 (see 
). 
Figure 2.76: RF Drive Source Menu
Use the up and down buttons to toggle between 
Internal VS Exciter
 and 
External Exciter
. Press the 
accept (checkmark) button to save the change. Press cancel (
X
) to discard changes and return to the 
previous menu. If you select 
External Exciter
, proceed to  
“Connecting an external analog exciter”
 
for connection details.
Connecting an external analog exciter
Configure the transmitter for an external analog exciter as follows:
1. Change the RF drive source.
2. Turn off the transmitter, remove it from its host cabinet and place it on a suitable work 
surface.
3. Remove the top cover.
4. Disconnect W5P1 from A1J1 and connect it to J4 on the inside of the box.
5. Re-install the top cover and re-insert the transmitter in its host cabinet.
6. With a user-supplied CAT5 cable, connect a wire between A1J1-7 (RF mute) and the the RF 
mute input on the external exciter. Note: The RF mute signal from the VS300 is active low 
and will not function if the external exciter is not configured in the same way.
Note: 
Configuration of the RF drive source is only available using the front panel display.