PRELIMINARY M0121A1A_uc.doc
 
3.1.2  Wall Mounting Procedure  
 
•  Check the wall mounting kit and the wall to determine their suitability. 
 
•  The maximum distance between the Node C and the Interface Unit depends on 
the length of the cable bridge by which they will be connected (see table 3-1 
Mounting distance
). Thus, before marking the mounting positions, check the 
length of the cable bridge and make sure to install the units at a suitable distance. 
 
Mounting style: 
beside each other* 
one above the other** 
Length of cable bridge:  500 mm  800 mm  2000 mm  only 2000 mm possible 
Maximum distance 
140 mm  400 mm  1600 mm  1000 mm (min.=300 mm)
*   Maximum distance is referring to distance between the cabinet sides 
**  It is recommended to install the Node C above the 
Interface Unit
; max. distance is the distance 
between top of lower and bottom of upper unit  
table 3-1 Mounting distance  
Note:  The following figures show units that are mounted beside each 
other. To install one above the other proceed in the same way, also 
observing the specified mounting distance from table 3-1
•  Mark the position of the eight drilling holes (four per unit) for the Node C and 
Interface Unit according to figure 3-1. Please observe that the figure always 
shows a pair of drill holes for each position. Only drill one of each pair.  
 
 