2.6.1  F-Connector installing instruction 
 
To avoid water intrusion to the AIR transceiver a self-vulcanization tape must be applied to 
the outdoor connector as shown in the picture below. It is necessary to apply the tape at the 
base of the trans-connector and move up in at least two wraps at  long of the whole trans- 
connector, connector and 1 to 2 cm over the cable. The tape should be wrapped with a low 
pulling  force.  The  tape  must  not  be torn  in  the  process  of  wrapping.  If  the  tape  is  applied 
with  to  high  pulling  force,  the  tape  can  break  under  environmental  influences.  On  every 
wrap the tape must cover at least half of the first applied wrap along the whole length of the 
trans-connector, connector and 1 to 2 cm of cable. 
 
 
Figure 10: F-connector seal