ENGINEERING 
Documentation 
Revision:
 1.6
Date:
24-May-17
Title:
TND540 Requirement 
Proprietary and Confidential
 
This document contains confidential and property information which belongs to Rand McNally, Inc.  This 
document may not be copied, reproduced, or transmitted to others in any manner, nor may any use of the 
information on this document be made, except for the specific purposes for which it is transmitted to the 
recipient without prior written consent of Rand McNally, Inc. 
 
Notes 
7.1  Display Brightness and Uniformity 
The methods of testing backlight brightness (luminance) and uniformity are defined below.  Measurements shall 
be performed with a full white pattern on the display using a (TBD) Luminance Meter (Model xxxxx or equivalent).  
The display should be operating for at least 10 minutes prior to test to ensure stability of the backlight and stray 
light on the display or into the luminance meter should be avoided. 
 
Figure 7.1 – Display Measurement Points
 
7.1.1 
Brightness 
Brightness  or  luminance  is  determined  using  the  5-spot  method.    This  consists  of  measuring  the  luminance 
perpendicular to the screen at 5 specific points (P1, P3, P5, P7, P9).  The average of three measurements at each 
point will be combined and divided by the number of points to obtain the average brightness.  This value should be 
equal to or greater than 343 nits as specified herein.
 