6、Installation steps (recommended by a professional 
technician) 
(1)  Draw a 15 cm long at the ready to install the horizontal line 
(2)  Unscrew counterclockwise Smoke fixed base 
(3)  Fixed  two  large  holes  align  horizontal  line  marks  the  position  of  the 
screws 
(4)  Using  an  electric  drill  (5mm  bits)  to  drill  a  hole  and  buried  in  two 
plastic nails (Gecko) 
(5)  Lock the screws to fix the base 
(6)  Align  the  Smoke  installation  well  fixed  base,  yield  to  clockwise, 
combined with the Smoke as a whole. Try to Smoke in order to make 
sure it is installed properly. 
 
 
 
7、Smoke Specification
 
  Induction type: photoelectric detection of smoke 
Smoke detection sensitivity: UL217 (factory default) 
Power supply:  1.5V two  AA alkaline batteries (normal standby mode,  uses about 18 
months) 
Built-in alarm sound mode: UL   
Working temperature:-40 ° c ~85 ° c   
Operating humidity: 0~95% 
Interface: IEEE802.15.4 
Frequency Range: 2.4-2.483GHz 
Transmission Speed: 250Kbps 
Transmission Power: 18dBm (Default) 
Transmission Range: 150M(Line of Sight) 
Sensitivity: -95dBm   
Size:114mm*114mm*63mm 
8、Zigbee reset connecting Gateway:
 
Pairing has to be replaced, you will need to open the body back 
panel  base,  locate  the  battery  place  the  top  button,  and  continue  to 
press the button for three seconds, the product will enter the pairing 
search  and  automatic  pairing  mode,  this  pairing  is  a  Gateway 
connecting the power for two minutes before they can match。 
 
This device is Fixed installation, so the minimum distance from 
body is 20cm 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
This device complies with part 15 of the FCC Rules. 
Operation is subject to the following two conditions: (1) 
This device may not cause harmful interference, and (2) 
this device must accept any interference received, 
including interference that may cause undesired 
operation. 
Any Changes or modifications not expressly approved 
by the party responsible for compliance could void the 
user's authority to operate the equipment. 
Note: This equipment has been tested and found to 
comply with the limits for a Class B digital device, 
pursuant to part 15 of the FCC Rules. These limits are 
designed to provide reasonable protection against 
harmful interference in a residential installation. This 
equipment generates uses and can radiate radio 
frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful 
interference to radio communications. However, there is 
no guarantee that interference will not occur in a 
particular installation. If this equipment does cause 
harmful interference to radio or television reception, 
which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the 
interference by one or more of the following measures: 
-Reorient or relocate the receiving antenna. 
-Increase the separation between the equipment and 
receiver. 
-Connect the equipment into an outlet on a circuit 
different from that to which the receiver is connected. 
-Consult the dealer or an experienced radio/TV 
technician for help.