Examples of Instance 101/151 
 
Access the inverter parameter is enabled using byte 4 to 6 of this Instance. 
Set the communication number of the parameter to byte 4, 5 (Index), and the value to byte 6, 7 (Data). 
 
c Read the parameter cmod (Command mode selection, communication number is 0003). 
Instance 
Byte  15 14 13 12 11 10 9
8
7
6
5
4
3  2  1  0 
Hex. 
5,  4 
0
0
0
0 0 0 0
0
0
0
1 1 
0x0003 
Output Instance 101 
7,  6 
-
-
-
-
- -
-
-
-
-
Input Instance 151 
5, 4 
0  0  0
0
0
0 0 0 0
0
0
0
1 1 
0x0003 
(cmod  is  0.) 
7,  6 
0
0
0
0 0 0 0
0
0
0
0x0000 
 
 
 
 
 
 
 
 
 
 
 
 
 
d Read the parameter f268 (Initial value of UP/DOWN frequency). 
Instance 
Byte  15 14 13 12 11 10 9
8
7
6
5
4
3  2  1  0 
Hex. 
5,  4 
0
0
0
0 0 1
1
0
0 0 0  0x0268 
Output Instance 101 
7,  6 
-
-
-
-
-
-
-
-
-
-
Input Instance 151 
5, 4 
0  0  0
0
0
0 0 1
1
0
0 0 0  0x0268 
(f268 is 60.0Hz.) 
7, 6 
0  0  0
1
0
1
1
1
1
1
1
0 0 0 0  0x1770 
 
 
 
 
 
 
 
 
 
 
 
 
 
3 Write “60 (Hz)” to the parameter sr1 (Preset speed 1, communication number is 0018). 
Instance 
Byte  15 14 13 12 11 10 9
8
7
6
5
4
3  2  1  0 
Hex. 
5, 4 
0
0
0
0 0 0 0 0
0
1
0 0 0  0x8018 
Output Instance 101 
7, 
6  0 0 0
1
0
1
1
1
1
1
1
0 0 0 0  0x1770 
5, 4 
0
0
0
0 0 0 0 0
0
1
0 0 0  0x8018 
Input Instance 151 (OK) 
7, 
6  0 0 0
1
0
1
1
1
1
1
1
0 0 0 0  0x1770 
Input Instance 151 (NG) 
5, 4 
1 1 
0
0
0
0 0 0 0 0
0
1
0 0 0  0xC018
(Error code *) 
7, 6 
0  0  0
1
0
0 0 0 0
0
0
0 0 0 0  0x1100 
 
*Data of "Error code" 
0x1100: Data out of range 
0x1101: Bad address