Zebra 77660 用户手册

下载
页码 234
38
Z4Mplus and Z6Mplus Maintenance Manual
13358L Rev. 1 11/17/03
Section 2
Operations Overview
Figure 2-13.   Adjusting the Optional Transmissive Sensor
Select Media Sensor
The Z4Mplus/Z6Mplus printers can be configured to select either of the sensors. By 
default the printer is set to Auto Select during auto-calibration.
The Sensor Select setting can be changed from the LCD menu (see the User Guide), or via 
ZPL II. The format for the ^JS instruction is as follows:
^JSx
Where
^JS
=Sensor Select
x
=Type of sensor
A
=Auto Select
R
=Reflective Sensor
T
=Transmissive Sensor
The sensor can be selected from the .
Transmissive
Sensor
Printhead
Open Lever
Printhead
Assembly
Rear View of Sensor - Inset A
Adjustment
Tab Slider
White Vertical
Marks
Front View of Sensor - Inset B
Adjustment
Tab
Note • 
Changing the Sensor Select setting via the front panel or ZPL II will initiate an 