Intermec 069427-003 用户手册
nugget
Replacing Parts
2-25
2
• E1022 linear imager assembly (P/N 072612S-001)
To replace the E1022 linear imager
1. Open the terminal. For help, see “Opening the Terminal” on page 2-4.
2. (2415 only) Remove the radio
card from the main PCB.
a.
Remove the screw holding the
retaining block in place, and
remove the retaining block.
retaining block in place, and
remove the retaining block.
b. Slide the radio card out of the
connector on the main PCB.
Note: The antenna cables are not
shown for clarity.
shown for clarity.
241XM016.eps
Radio
card
card
Retaining
block
block
Screw
3. Remove the four screws holding the E1022 linear imager assembly in place.
241XM053 .eps
Screw
(4 places)
(4 places)
Scan
window
window
Antenna
E1022
linear
imager
linear
imager
4. Remove the E1022 linear imager assembly from the bottom cover.