Intermec 069427-003 用户手册

下载
页码 69
nugget
 
 
Replacing Parts 
2-27 
2
3. Remove the scanner flex cable from the PDF 417 PCB assembly.
241XM055 .eps
PDF 417
PCB assembly
Scanner
flex cable  
Bottom
cover 
4. Remove the PDF 417 PCB assembly.
5. Connect the scanner flex cable to the new PDF 417 PCB assembly.
6. (2415 only) Install the radio card.
a.
Compare the connector tabs on the radio card to the connector on the main PCB
to determine which way to insert the card.
b. Slide the radio card into the connector. Firmly press the card into the connector
until it stops.
c.
Install the retaining block on the main PCB and tighten the screw to 0.226 Nm
(2 in-lb).
7. Close the terminal. For help, see “Closing the Terminal” on page 2-36.
Replacing the Scanner Lens or E1022 Scan Window 
Because finger oils can dissolve the reflective coating of the plastic mirrors, always
wear finger cots or non-powdered latex gloves when handling optical parts.
To replace the scanner lens or E1022 scan window, you need the following tools:
•  #1 Phillips screwdriver
•  Torque screwdriver