Hynix 4GB PC3-12800 HMT351S6CFR8C-PB 用户手册

产品代码
HMT351S6CFR8C-PB
下载
页码 48
Rev. 1.0/Sep. 2012
12 
AC & DC Operating Conditions
Recommended DC Operating Conditions
Notes:
1. Under all conditions, VDDQ must be less than or equal to VDD.
2. VDDQ tracks with VDD. AC parameters are measured with VDD and VDDQ tied together.
Recommended DC Operating Conditions
Symbol
Parameter
Rating
Units Notes
Min.
Typ. 
Max.
VDD
Supply Voltage
1.425
1.500
1.575
V
1,2
VDDQ
Supply Voltage for Output
1.425
1.500
1.575
V
1,2