MEAN WELL LPV-35-24 产品宣传页

下载
页码 2
SPECIFICATION
MODEL
LPV-35-5
LPV-35-12
LPV-35-15
LPV-35-24
LPV-35-36
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT(max.)
LEAKAGE CURRENT
SAFETY STANDARDS
HARMONIC CURRENT
EMS IMMUNITY
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER CURRENT
Note.4
OVER VOLTAGE
5V
12V
15V
24V
36V
6A
3A
2.4A
1.5A
1A
0 ~ 6A
0 ~ 3A
0 ~ 2.4A
0 ~ 1.5A
0 ~ 1A
30W
36W
36W
36W
36W
80mVp-p
120mVp-p
5.0%
120mVp-p
150mVp-p
150mVp-p
6.0%
1.0%
4.0%
500ms, 20ms / 230VAC 5
at full load
00ms, 20ms / 115VAC
90 ~ 264VAC
47 ~ 63Hz
77%
85%
2.0%
85%
86%
86%
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
41.4 ~ 48.6V
1.1A/115VAC
0.7A/230VAC
COLD STAR 30A/115VAC
60A/230VAC
0.25mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
-30 ~ +75
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Design refer to UL1310 Class 2,TUV EN60950-1, CAN/CSA C22.2 No. 223-M91, EN61347-2-13, IP66
743.5Khrs min.
MIL-HDBK-217F (25
)
148*40*30mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the derating curve for more details.
5. The power supply is considered a component which will be installed a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
0.34Kg; 40pcs/14.6Kg/0.63CUFT
Protection type : Shut down o/p voltage, re-power on to recover
35W Single Output Switching Power Supply
Features :
L P V- 3 5
s e r i e s
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
EMI CONDUCTION & RADIATION
SAFETY &
EMC
PROTECTION
50ms/230VAC
16ms/115VAC at full load
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms/500VDC 25
70%RH
File Name:LPV-35-SPEC 2008-06-03
Constant voltage mode power supply
Universal AC input / Full range
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Low cost, high reliability
Suitable for LED lighting and moving sign applications
2 years warranty
Fully isolated plastic case