MEAN WELL LPV-35-24 数据表

下载
页码 2
SPECIFICATION
MODEL
LPV-35-5
LPV-35-12
LPV-35-15
LPV-35-24
LPV-35-36
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(max.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
5V
12V
15V
24V
36V
5A
3A
2.4A
1.5A
1A
0 ~ 6A
(Note.7)
0 ~ 3A
0 ~ 2.4A
0 ~ 1.5A
0 ~ 1A
30W
36W
36W
36W
36W
80mVp-p
120mVp-p
¡Ó5.0%
120mVp-p
150mVp-p
150mVp-p
¡Ó6.0%
¡Ó1.0%
¡Ó4.0%
500ms, 20ms / 230VAC 5
at full load
00ms, 20ms / 115VAC
90 ~ 264VAC
127 ~ 370VDC
47 ~ 63Hz
77%
84%
¡Ó2.0%
84%
85%
85%
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
41.4 ~ 48.6V
1.1A/115VAC
0.7A/230VAC
0.25mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
-30 ~ +65
¢J (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
¢J
¡Ó
¢J
¢J
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1310, CAN/CSA C22.2 No. 223-M91, IP67 approved ; design refer to TUV EN60950-1
743.5Khrs min.
MIL-HDBK-217F (25
)
¢J
148*40*30mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. LPV-35-5 can provide 6A of output current continuously. Based on the requirement of UL1310 class 2, the output current is only certified up to 5A for
the test report of LPV-35-5.
8. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
9. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
¢J
0.34Kg; 40pcs/14.6Kg/0.63CUFT
Protection type : Shut down o/p voltage, re-power on to recover
35W Single Output Switching Power Supply
¡½
Features :
L P V- 3 5
s e r i e s
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
50ms/230VAC
16ms/115VAC at full load
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25
/ 70% RH
¢J
File Name:LPV-35-SPEC 2012-12-26
Constant voltage design
Universal AC input / Full range
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
Fully encapsulated with IP67 level
Class 2 power unit
ass LPS
Suitable for LED lighting and moving sign applications
100% full load burn-in test
Low cost, high reliability
2 years warranty
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¢º
(Note.9)
Fully isolated plastic case
Class
power unit, no FG
P
(Note.8)
IP67
LPS
EMC IMMUNITY
EMC EMISSION
COLD START 55A(t
=510 s measured at 50% I
) at 230VAC
width
peak
£g