Omron G2R-1-SNI 230 VAC PCB Mount Relay 230Vac 1 CO, SPDT G2R-1-SNI 230 VAC 数据表

产品代码
G2R-1-SNI 230 VAC
下载
页码 19
G2R
G2R
5
PCB/Fully sealed Relays
Item
General-purpose (single contact)
Bifurcated contact
Number of poles
1 pole
2 poles
1 pole
Load
Resistive load
(cos
$
= 1)
Inductive load
(cos
$
= 0.4;
L/R = 7 ms)
Resistive load
(cos
$
= 1)
Inductive load
(cos
$
= 0.4;
L/R = 7 ms)
Resistive load
(cos
$
= 1)
Inductive load
(cos
$
= 0.4;
L/R = 7 ms)
Rated load
8 A at 250
VAC;
8 A at 30 VDC
6 A at 250 VAC;
4 A at 30 VDC
4 A at 250
VAC;
4 A at 30 VDC
1.5 A at 250
VAC;
2.5 A at 30 VDC
5 A at 250
VAC;
5 A at 30 VDC
2 A at 250 VAC;
3 A at 30 VDC
Rated carry current
8 A
4 A
5 A
Max. switching voltage
380 VAC, 125 VDC
380 VAC, 125 VDC
380 VAC, 125 VDC
Max. switching current
8 A
4 A
5 A
Max. switching power
2,000 VA,
240 W
1,500 VA,
120 W
1,000 VA,
120 W
375 VA,
75 W
1,250 VA,
150 W
500 VA,
90 W
Min. permissible load
100 mA at 5 VDC
10 mA at 5 VDC
1 mA at 5 VDC
Note:
P level:
%
60
= 0.1 x 10
-6
/operation
Latching Relays
Number of poles
1 pole
2 poles
Load
Resistive load
(cos
$
= 1)
Inductive load
(cos
$
= 0.4; L/R = 7
ms)
Resistive load
(cos
$
= 1)
Inductive load
(cos
$
= 0.4; L/R = 7
ms)
Rated load
5 A at 250 VAC;
5 A at 30 VDC
3.5 A at 250 VAC;
2.5 A at 30 VDC
3 A at 250 VAC;
3 A at 30 VDC
1.5 A at 250 VAC;
2 A at 30 VDC
Rated carry current
5 A
3 A
Max. switching voltage
380 VAC, 125 VDC
380 VAC, 125 VDC
Max. switching current
5 A
3 A
Max. switching power
1,250 VA, 150 W
875 VA, 75 W
750 VA, 90 W
375 VA, 60 W
Min. permissible load
100 mA at 5 VDC
10 mA at 5 VDC
Note:
P level:
%
60
= 0.1 x 10
--6
/operation
Characteristics
Standard Relays
Item
1 pole
2 poles
Contact resistance
30 m
!
max. (high-capacity type: 100 m
!
max.)
50 m
!
max.
Operate (set) time
15 ms max.
Release (reset) time
AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.)
Max. operating frequency
Mechanical:
18,000 operations/hr
Electrical:
1,800 operations/hr (under rated load)
Insulation resistance
1,000 M
!
min. (at 500 VDC)
Dielectric strength
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts
of same polarity
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
3,000 VAC, 50/60 Hz for 1 min between
contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between
contacts of same polarity
Vibration resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Destruction: 1,000 m/s
2
Malfunction: 200 m/s
2
when energized; 100m/s
2
when no energized
Life expectancy
Mechanical: AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical:
100,000 operations min. (at 1,800 operations/hr under rated load)
Ambient temperature
Operating: --40
"
C to 70
"
C (with no icing)
Storage:
--40
"
C to 70
"
C (with no icing)
Ambient humidity
Operating: 35% to 85%
Storage:
35% to 85%
Weight
Approx. 17 g (plug-in terminal: approx. 20 g)
Note:
Values in the above table are the initial values.
*2,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A socket is mounted.