6.3.5.1. CONTACT_GET_SET_PWR_UP_SEQUENCE 
 
This Escape command is used to get or set the following parameters: 
x  Smart card Power-on sequence 
x  Delay between successive Activation retires 
x  Enable/Disable any Voltage Class 
 
As soon as card insertion is detected and Power ON message is received from the host, the 
firmware will start Activation with the configured voltage sequence. If the Activation fails, it will 
wait for the configured Activation delay and then retry with the next enabled Voltage class. If 
power up succeeds at an operating voltage, the firmware will continue card communication at 
that voltage. If power up fails in all the enabled operating voltages, then the firmware will report 
an error. 
 
Input: 
The first byte of the input buffer will contain the escape code. The next byte shall contain the 
function to be performed. Third byte shall contain the parameter for the function. 
 
 
 
Byte0 
Byte1 
Byte2 
Value  Description 
Escape 
code(0x04) 
 
0x00 
Starts with Class C voltage.  
(1.8V – 3V – 5V order) 
 
0x01 
Starts with Class A voltage. 
(5V – 3V – 1.8V order) 
0x08 
Time delay between resets 
Delay value in milliseconds 
0x09 
Enable/Disable a Voltage 
Class 
Bit Map of all Voltage Classes  
[Bit0 – Class A; Bit1 – Class B; 
Bit2 – Class C] 
Set bit to enable the Voltage 
class 
Clear bit to disable the Voltage 
class  
0xFE 
Retrieves all the Activation 
Configuration 
0xFF 
Retrieves the current Power up 
sequence