Merten Insert Electronic switch insert System M, System Area, Aquadesign MEG5151-0000 MEG5151-0000 用户手册

产品代码
MEG5151-0000
下载
页码 4
V5151-581-00 12/11
Insert with mechanical push-buttons via PlusLink
A Electronic switch insert, 2-gang
B Mechanical push-buttons (toggle mode)
Insert in combination with sending devices via 
PlusLink 
(here shown with side controller Plus)
A Electronic switch insert, 2-gang
B Side controller Plus 1-gang / 2-gang (sending de-
vice)
Installing the device
A Electronic switch insert, 1-gang/2-gang
B Frame
C Module (see function overview)
D Rockers for module
PL2
PL1
2
1
L
L
N
B
A
B
PL2
PL1
2
1
L
PL
L
L
N
PL
L
A
B
B
B
A
C
D
|
The insert is shown here in operation in combina-
tion with a push-button module. More details on 
how to operate the various modules can be found 
in the corresponding operating instructions.
Switching loads on/off (1-gang insert)
Switching loads on/off (2-gang insert)
• right button: channel 1
• left button: channel 2
Retrieving light scenes (1-gang insert)
(only for push-button module, 2-gang)
Standard scenes
All devices are delivered from the factory with preset-
tings for a light scene.
Operating the insert
S1:
light on
S2: light 
off
<  0,5 s
<  0,5 s
<  0,5 s
< 0,5 s
Controlling loads from another location 
with sending devices via PlusLink. For 
example:
• Central unit insert with module
• Side controller Plus, 1-gang/2-gang
• Mechanical push-button
• External sensor
Example operation 1:
When the push-button module on the central unit insert 
is pressed, all loads in the PL line are controlled together.
• Short press on the push-button(< 0.5 s): switching on/
off
A Electronic switch insert in PL line 1
B Central unit insert with module
Example operation 2:
|
When a mechanical push-button is used, we rec-
ommend connecting only one insert. With two or 
more inserts, simultaneous switching of the loads 
is no longer guaranteed.
A Electronic switch insert
B Mechanical push-button
Example operation 3:
A Electronic switch insert with push-button module 
Comfort Plus, 1-gang / 2-gang
B Brightness sensor with wind sensor interface
B
A
A
PL4 PL3 PL2
PL1
<  0,5 s
<  0,5 s
B
A
<  0,5 s
PL
PL
B
A
The device regularly switches off during operation
• Allow the device to cool down and reduce the con-
nected load.
The load cannot be switched back on.
• Allow the device to cool down and reduce the con-
nected load.
• Rectify any possible short circuits.
• Renew defective loads.
Merten GmbH, Fritz-Kotz-Str. 8, D-51674 Wiehl
www.merten.com
Service Center:
Technical support / InfoLine:
What should I do if there is a problem?
Technical data
Nominal voltage:
AC 220/230 V ∼, 50/60 Hz
MEG5151-0000
Switching capacity:
50-420 VA
Energy-saving lamps: 12-100 VA
Philips Master LED 
bulb:
max. 40 W
Outputs:
1
MEG5152-0000
Switching capacity per 
channel:
50-220 VA
Energy-saving lamps: 12-40 VA
Philips Master LED 
bulb:
max. 40 W
Outputs:
2
Neutral conductor:
not required
Connecting terminals:
Screw terminals for max. 2x 
2.5 mm
2
 or 2x 1.5 mm
2
Protection
16 A circuit breaker
Features:
• Short-circuit-proof
• overload-proof
Merten GmbH
Phone: +49 2261 702-204
Fax:
+49 2261 702-136
E-Mail: servicecenter@merten.de
Phone: +49 2261 702-235
Fax:
+49 2261 702-680
E-Mail: infoline.merten@schneider-electric.com