Operating Conditions 
Operate the STD35 only with a supply voltage between  7-32V DC and have in mind the polarity! (see 
picture1) Use a stabilized power supply with minimum 1A output current. (We recommend using only 
the original CEP power supply). If you use a mains adapter for power supply it has to conform to the 
VDE regulations.  
  Loads connected to the device are not allowed to exceed 30 W per relay.  
  The maximum output voltage is 250 V AC for output 1 and 2 and 30V DC for outputs 3-5 
  The maximum switching current for output 1 and 2 is 5A  and for  outputs 3-5 it is 1A 
  When installing the device make sure that the supply cable has a sufficient diameter 
  During operation the temperature must be in the range -30° to +75° Celsius.  
  Protect the PCB of the device from humidity, spray water and heat. 
  In case of condensation allow a period of about 2 hours for acclimatisation.  
  Do not operate the device in areas where inflammable gas, vapours, or dust are or could be present.  
  Do not expose the device to heavy vibrations. 
  The unit may only be repaired by a specialist. 
  Only  original  parts  have  to  be  used  when  repairing  the  unit.  The  use of  differing  spare  parts  can 
cause serious material loss or personal injury. 
  No special positioning is required to operate the device. 
 
Application Areas 
The device is designed for the remote switching of devices via the GSM network as well as the remote 
retrieval of status information of the inputs and the generation of SMS messages or E-Mails after status 
has changed at the inputs. A different utilization of the device other than the ones described here is not 
allowed.  
 
Introduction 
The STD35 is a telemetry module which is easy to install and simple to use. It can be configured using 
any GSM mobile phone, SMS capable software, or the CEP STD35 configuration tool (sold separately). 
With the STD35 you can control five relays and monitor the status of three digital and two analog inputs 
with one or several standard mobile phones.  
Apart from the STD35 you only need a valid SIM Card from any network provider (GSM850 / 900 / 1800 
or 1900 MHz)  
While using prepaid SIM-cards, always keep aware of the amount of remaining budget left on the card, 
so that in case of alarms a message still can be transmitted. 
Typical fields of application are: 
  Opening (garage) doors 
  Switching on and off light and alarm devices as well as generating alarm messages (SMS or E-Mail)  
  Retrieval of information from door sensors, movement sensors or level sensors  
  etc. 
You can for example open your garage door with a call or get a message (vian SMS or E-Mail) in case 
your house alarm system gets triggered. E-Mail