Cep Terminals 04100 GSM Remote Switch Control Module 04100 数据表
产品代码
04100
Figure 1: Positioning of the connectors on the STD35
Connectors
As described in Figure 1 the STD35 has 5 Green Screw terminals.
Outputs
(Blue)
Inputs
(Purple)
1
Output 1 a
1
Input 1 +
2
Output1 b
2
Input 2 +
3
Output 2 a
3
Input 3 +
4
Output 2 b
4
Input 1-5 GND
5
Output 3 a
5
Input 4 (AIN1) +
6
Output 4 a
6
Input 5 (AIN2) +
7
Output 5 a
8
Output 3/4/5 b
Table 1: Available Connectors
The first two terminal blocks (highlighted in blue) are the output terminals. Here, electrical loads are
connected to the respective relay.
The third and fifth row of screw terminals (marked in purple) correspond to the Inputs. The inputs
are activated as soon as a voltage is applied within the specified range between the terminals of the
optocoupler.
optocoupler.