L M K 0 4 8 1 6   E V A L U A T I O N   B O A R D   O P E R A T I N G   I N S T R U C T I O N S  
 
 
 
 
SNLU107 
3. Program/Load Device 
 
Assuming the Port Setup settings are correct, press the 
“Ctrl+L” shortcut or click “Keyboard Controls”  
“Load Device” from the menu to program the device to 
the current state of the newly loaded LMK04816 file.   
 
Once the device has been initially loaded, CodeLoader 
will automatically program changed registers so it is 
not necessary to re-load the device upon subsequent 
changes in the device configuration.  It is possible to disable this functionality by ensuring there 
is no checkmark by the “Options”  “AutoReload with Changes.” 
 
Because a default mode will be restored in the next step, this step isn‟t really needed but included 
to emphasize the importance of pressing “Ctrl+L” to load the device at least once after starting 
CodeLoader, restoring a mode, or restoring a saved setup using the File menu. 
 
See Appendix A: CodeLoader Usage or the CodeLoader 4 instructions located at 
 for more information on Port Setup.  Appendix H: 
Troubleshooting Information contains information on troubleshooting communications. 
 
4. Restoring a Default Mode 
Click “Mode”  “LMK04816, 122.88 MHz VCXO, 122.88 MHz CLKin1”; then press Ctrl+L. 
 
 
Figure 5: Setting the Default mode for LMK04816 
 
For the purpose of this walkthrough, a default mode will be loaded to ensure a common starting 
point.  This is important because when CodeLoader is closed, it remembers the last settings used 
for a particular device.  Again, remember to press Ctrl+L as the first step after loading a default 
mode. 
Figure 4 – Loading the Device