Texas Instruments Hercules TMS570LS04x/03x LaunchPad Evaluation Kit LAUNCHXL-TMS57004 LAUNCHXL-TMS57004 数据表

产品代码
LAUNCHXL-TMS57004
下载
页码 106
SPNS186A – OCTOBER 2012 – REVISED SEPTEMBER 2013
3.5
Power Consumption Over Recommended Operating Conditions
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
f
HCLK
= 80MHz
V
CC
digital supply current (operating mode)
135
(1)
mA
f
VCLK
=
80MHz,
Flash
in
pipelined
mode, V
CCmax
I
CC
LBIST clock rate =
V
CC
Digital supply current (LBIST mode)
145
(2) (3)
mA
45MHz
PBIST ROM clock
135
(2) (3)
VCC Digital supply current (PBIST mode)
mA
frequency = 80MHz
I
CCREFHI
AD
REFHI
supply current (operating mode)
AD
REFHImax
3
mA
I
CCAD
V
CCAD
supply current (operating mode)
V
CCADmax
45
(4)
I
CCIO
V
CCIO
Digital supply current (operating mode.
No DC load, V
CCmax
mA
I
CCP
V
CCP
pump supply current
Read mode
read from one bank
65
(4)
I
CCP,
and program or
3.3V supply current
mA
I
CCIO,
I
CCAD
erase another,
V
CCPmax
(1)
The maximum I
CC,
value can be derated
linearly with voltage
by 0.76 mA/MHz for lower operating frequency when f
HCLK
= f
VCLK
for lower junction temperature by the equation below where T
JK
is the junction temperature in Kelvin and the result is in milliamperes.
60 - 0.001 e
0.026 T
JK
(2)
The maximum I
CC,
value can be derated
linearly with voltage
for lower junction temperature by the equation below where T
JK
is the junction temperature in Kelvin and the result is in milliamperes.
60 - 0.001 e
0.026 T
JK
(3)
LBIST and PBIST currents are for a short duration, typically less than 10ms. They are usually ignored for thermal calculations for the
device and the voltage regulator
(4)
Maximum current requirement of the three combined supplies
20
Device Operating Conditions
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: