Bauser BZ/IZ 12-24V/DC BZ/IZ Digital counter - Twin technology Assembly dimensions 45 x 22 mm 3840.2.1.1.1.2 Twin3 数据表

产品代码
3840.2.1.1.1.2 Twin3
下载
页码 11
6
Technical specifications of the single and double counters
On this page you will find the complete technical specifications and drawings
of the digital single and double counters.
Please note:
On pages 10 to 12 you will find variants with signal- or relay output or with two permanent indicati-
ons. Voltage-free counters, which operate with a lithium battery, will be shown on pages 7 to 9.
The smart double counters are also available as modules. Find more information on pages 18 to 22.
black plastic
LC-display with 7 digits (only active while connected)
7 mm
12 - 24 V DC / ±25 %
110 - 240 V AC 50/60 Hz / ±10 %
24 - 48 V DC / ±25 %
24 V AC/DC / ±10 %
12 - 24 V DC and 24 - 48 V DC / < 5 mA
24 V AC / DC / < 10 mA
110 - 240 V AC 50/60 Hz / < 15 mA
-30 ° C to +70° C
-40 ° C to +80° C
plug connection 6,3 x 0,8 mm /90° bent or terminal connection
without, manual or electrical
without reset button IP 65, with reset button IP 54
20 g according to SAEJ1378, 1 g (10...500 Hz) according to EN 60068-2-34
55 g according to SAEJ1378, 30 g (18 ms) according to EN 60068-2-27
25 g (6 ms) according to EN 60068-2-29
EN 55011, EN 61000-6-2
EN 61010, protection class II
, UL, cUL
30 or 200 Hz = DC-counter
10 Hz = AC-counter
EEPROM (min. 25 years)
retaining clip
39, 42 or 57 g.
housing:
indication:
character height:
operating voltages:
special voltages
(at additional cost):
current consumption:
ambient temperature:
stocking temperature:
electrical connection:
reset:
protection:
vibration resistance:
shock resistance:
EMC:
industrial norm:
approval:
counting frequency /
pulse counter:
data storage:
fixing:
weight:
drawing:
Ø 56 mm with glass ring
drawing: 48 x 48 mm
drawing: 48 x 24 mm
y
Digital time
and pulse counters
Technical specifications: